YY/T 0106-2008 Translated English of Chinese Standard. (YYT 0106-2008, YY/T0106-2008, YYT0106-2008): General specifications for medical diagnostic X-ray equipment [Buy--download True-PDF in 3-second: https://play.google.com/books > Sign in > This BOOK > "3-dots" > Export > Save as "*.pdf"]https://www.chinesestandard.net, 2016/06/03 - 15 ページ This Standard specifies the classification, requirements and test methods of medical diagnostic X-ray equipment. This Standard is applicable to medical diagnostic X-ray equipment. For medical diagnostic X-ray equipment with national or industrial specific standard requirements, it shall perform the appropriate national or industrial specific standards. This Standard is not applicable to X-ray equipment for computed tomography. |
この書籍内から
検索結果1-5 / 13
1 ページ
... Replacing YY/T 0106-2004 General specifications for medical diagnostic X-ray equipment 医用诊断 X 射线机通用技术条件 Issued on: October 17, 2008 Implemented on: January 1, 2010 Issued by: China Food and Drug Administration Foreword ...
... Replacing YY/T 0106-2004 General specifications for medical diagnostic X-ray equipment 医用诊断 X 射线机通用技术条件 Issued on: October 17, 2008 Implemented on: January 1, 2010 Issued by: China Food and Drug Administration Foreword ...
2 ページ
General specifications for medical diagnostic X-ray equipment [Buy--download True-PDF in 3-second: https://play.google.com/books > Sign in > This BOOK > "3-dots" > Export > Save as "*.pdf"] https://www.chinesestandard.net. Foreword ...
General specifications for medical diagnostic X-ray equipment [Buy--download True-PDF in 3-second: https://play.google.com/books > Sign in > This BOOK > "3-dots" > Export > Save as "*.pdf"] https://www.chinesestandard.net. Foreword ...
3 ページ
... medical diagnostic X-ray equipment. Compared with YY/T 0106-2004, the main changes are as follows: - Rewrote Clause 1 and defined the application scope of this Standard; - Added Clause 3 Terms and definitions; - Revised Clause 4 to ...
... medical diagnostic X-ray equipment. Compared with YY/T 0106-2004, the main changes are as follows: - Rewrote Clause 1 and defined the application scope of this Standard; - Added Clause 3 Terms and definitions; - Revised Clause 4 to ...
4 ページ
... medical. diagnostic. X-ray. equipment. 1. Scope. This Standard specifies the classification, requirements and test methods of medical diagnostic X-ray equipment (hereinafter referred as X-ray equipment, for short). This Standard is ...
... medical. diagnostic. X-ray. equipment. 1. Scope. This Standard specifies the classification, requirements and test methods of medical diagnostic X-ray equipment (hereinafter referred as X-ray equipment, for short). This Standard is ...
5 ページ
書籍の閲覧制限を超えています.
書籍の閲覧制限を超えています.
多く使われている語句
adjustment method adjustment range and/or intermittent mode angle measuring tool Anti-overload Braking force causes the maximum Collateral standard combination of X-ray comply with requirements conduct according conduct it according continuous mode and/or Current time product Deviation of X-ray diagnostic X-ray equipment Digital subtraction angiography following requirements force Practical operation Indicated value indirect fluoroscopic imaging Indirect photography industrial specific standards loading factors combination mammography X-ray equipment maximum output electric medical diagnostic X-ray Medical electrical equipment mode and/or intermittent national or industrial nominal electric power observe and determine output electric power Particular requirements photography and indirect Power resistor Power supply conditions product standard range and adjustment requirements and test requirements for safety specifications for medical standard shall stipulate Start-up force stipulate the adjustment stipulate the deviation subtraction angiography DSA Terms and definitions tomography tool to measure tube voltage value value of angle value of length X-ray tube current X-ray tube voltage