隠しフィールド
ブックス I must get quit of the condensed steam and injection water, if I used a jet as in... の書籍検索結果
" I must get quit of the condensed steam and injection water, if I used a jet as in Newcomen's engine. Two ways of doing this occurred to me. First the water might be run off by a descending pipe, if an... "
Transactions - 4 ページ
Glasgow Archaeological Society 著 - 1868
全文表示 - この書籍について

A History of Engineering

Arthur Percy Morris Fleming, Harold John Brocklehurst - 1925 - 330 ページ
...saw that I must get rid of the condensed steam and injection water if I used a jet, as in Newcomen's engine. Two ways of doing this occurred to me. First, the water might be run off by a condensing pipe, if an off-let could be got at the depth of 35 or 36 feet, and any air might be extracted...

James Watt and the Steam Engine: The Memorial Volume Prepared for the ...

Henry Winram Dickinson, Rhys Jenkins - 1927 - 602 ページ
...passed the old washing house. I was thinking upon the engine . . . and gone as far as the Herd's House, when the idea came into my mind that as steam was...the pump large enough to extract both water and air. ... 7 had not walked further than the Golf-house when the whole thing was arranged in my mind.' Thus...

What Every Engineer Should Know about Inventing

Middendorf - 1981 - 172 ページ
...saw that I must get quit of the condensed steam and injection water, if I used a jet as in Newcomen's engine. Two ways of doing this occurred to me. First,...the pump large enough to extract both water and air. I had not walked farther than the Golf-house when the whole thing was arranged in my mind. Steam engines...

A History of Mechanical Inventions

Abbott Payson Usher - 1954 - 482 ページ
...the water might be run off by a descending pipe, if an offlet could be got at a depth of 35 or 3fi feet, and any air might be extracted by a small pump....the pump large enough to extract both water and air ... I had not walked farther than the Golf house, when the whole thing was arranged in my mind.' A...

Power from Steam: A History of the Stationary Steam Engine

Richard L. Hills - 1993 - 360 ページ
...saw that I must get quit of the condensed steam and injection water, if I used a jet as in Newcomen's engine. Two ways of doing this occurred to me. First...water might be run off by a descending pipe, if an outlet could be got at the depth of 35 or 36 feet, and any air might be extracted by a small pump;...

James Watt

Andrew Carnegie - 2001 - 260 ページ
...saw that I must get rid of the condensed steam and injection-water if I used a jet as in Newcomen's engine. Two ways of doing this occurred to me. First,...water might be run off by a descending pipe, if an omet could be got at the depth of thirty-five or thirty-six feet, and any air might be extracted by...

Watt's Perfect Engine: Steam and the Age of Invention

Ben Marsden - 2002 - 234 ページ
...saw that I must get quit of the condensed steam and injection water, if I used a jet as in Newcomen's engine. Two ways of doing this occurred to me. First the water might be run off by a descending pipe ... and any air might be extracted by a small pump; the second was to make the pump large enough to...

Great Inventors

100 ページ
...saw that I must get rid of the condensed steam and injection-water if I used a jet as in Newcomen's engine. Two ways of doing this occurred to me. First,...descending pipe, if an offlet could be got at the depth of thirty-five or thirt/-six feet, and any air might be extracted by a small pump. The second was to make...




  1. マイ ライブラリ
  2. ヘルプ
  3. ブックス検索オプション
  4. ePub をダウンロード
  5. PDF をダウンロード